Overview
Each SMOG-HOG® Type SHN self-contained unit is a two-stage Penney-type electrostatic air cleaner designed for industrial service. It incorporates a centrifugal blower with permanently lubricated ball bearings and is belt-driven by a totally enclosed fan-cooled motor. Airflow capacity is adjustable by means of a variable pitch motor pulley. High voltage, regulated switching (HVRS) power pack(s) provides up to 12 KVDC for ionizing and 6 KVDC for collection. The power pack(s) is UL recognized/CSA certified and is housed with an indicating lamp and other electrical components in a top mounted enclosure. Externally removable high voltage feed-through insulators are located in a side mounted enclosure. High voltage wiring is conduit-enclosed and external to the airstream. Each unit is equipped with an integral sump and, where applicable, a drain connection for runoff of collected liquid contaminants. A four-way adjustable exhaust diffuser(s) provides directional control of the cleaned air
APPLICATIONS & FEATURES
APPLICATIONS
Engineered to perform long-term, heavy-duty industrial air cleaning, SHN/SG units eliminate smoke, mist and dust generated by a variety of applications—brazing, casting, flame cutting, drilling, grinding, milling, screw machining and more. Also, these systems are available in a variety of sizes and versatile configurations to fit your company’s needs.
SHN/SG units are equipped with airflow capacities ranging from 400 to 9,000 CFM. Systems can be ducted, unducted, free hanging and machine-mounted, depending on your specific application— eliminating the need to give up valuable floor space in your facility!
ENSURE EMPLOYEE SAFETY WHILE MINIMIZING COSTS
SHN/SG mist collectors keep employees healthy and on the job by removing dangerous airborne contaminants that can cause respiratory problems. These powerful units eliminate dirty airborne particles before they settle on floors, land on expensive machinery or are inhaled—situations that can lead to accidents, workers’ compensation claims, OSHA compliance violations and expensive machine repairs.
Investing in the SHN/SG Series can also improve your company’s profitability by reducing energy and housekeeping costs. These systems recirculate air into your plant and reduce exhaust air make-up requirements up to 80%! Thousands of gallons of valuable resources such as cutting oils, lubricants, coolants and plasticizers are recycled each year by UAS’ SHN/SG Series customers.
CONTINUOUS CLEANING
SHN/SG units can be programmed to run continuously during and between shifts. This feature reduces the energy resources needed to power the system every day, as well as decreases the potential for contaminants to accumulate while the SHN/SG system is in the “off” mode.
PRODUCT ENHANCEMENTS REDUCE COSTS
UAS’ most recent improvement to the SHN/SG product line is the revolutionary Mist-Stop filter. Composed of heavy-duty aluminum mesh and a high-efficiency coalescing pad, the new filter dramatically reduces the amount of mist and smoke particles that pass through the Ionizer and ESP Collection Component. So, less time and money is spent servicing and cleaning a unit, because intervals between cleanings increase up to two to three times longer!
Another product enhancement is the newly expanded SHN cabinet design (pictured below). Now standard on all SHN units, the larger cabinet allows room for the 1″ aluminum mesh filter and optional 2″ Mist-Stop filter— eliminating the need to add an inlet plenum.
Mist-Stop filters are available for use on all SHN, SH and SG units that use an impingement plenum, as well as the newly expanded SHN systems.
SHN OR SG?
All SHN and SG units use the same electrostatic precipitator technology to clean industrial mist and oil smoke. Both systems are available in a variety of sizes and configurations depending upon your company’s application. However, there are a few differences to consider when choosing the right ESP mist collector.
SHN systems collect oil smoke and mist particles, and handle airflows from 400 to 5,200 CFM. Comprised of an ionizer section and an ESP collection cell, SHN units can accommodate additional filtration options for heavy-duty applications. These filters, as well as the ESP components, conveniently slide in and out of the system for easy manual cleaning. SHN units can be ducted, unducted, machine mounted and hung.
SG units collect high-volume oil smoke and coolant emissions, and are equipped for airflow capacities ranging from 2,200 to 9,000 CFM. Instead of using two separate components, these powerful systems employ a single ESP unicell, which combines the ionizer and collection cell. Supplemental filtration accessories are available, as well as an automated in-place cleaning option. SG systems can be ducted, unducted and hung.
Depending on your specific application, airflow requirements and size restrictions, a UAS representative can help you select the unit that matches your company’s industrial air quality need.
IN STOCK. Factory Fulfilled by Parker.
SHIPS WITHIN: 3-5 Weeks Depending on Options,
WARRANTY: For detailed warranty information, please contact us directly. Warranty For Parts and Service